Technology Stack (TXK) AutoConfig Context Variable Report| Entered Keywords | mwa | | Matched Context Variables | s_mwaPortNo, s_mwaTelnetPortNo, s_mwaDispatcherPort, s_mwaLogLevel, s_mwaLogRotate, s_mwaLogFileSize, s_mwaDropConnectionTimeout, s_mwaStaleSessionTimeout, s_mwaDispatcherThreadCount, s_mwaDispatcherClientsPerWorker, s_mwaJVMb, s_mwaActivateLOVByEnter, s_mwaSubmenuChangeOrgResp, s_mwatop, s_mwaname, s_mwastatus, s_mwalog, s_mwatimeout, s_mwactrl |
|
Context Variable : s_mwaPortNo |
|
|
| Description | MSCA Server Port Number | | Current Value | 10290-10295 | | Default Value | 10200 |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwaTelnetPortNo |
|
|
| Description | MSCA Telnet Server Port Number | | Current Value | 10290,10292,10294 | | Default Value | 10200 |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwaDispatcherPort |
|
|
| Description | MSCA Dispatcher Port Number | | Current Value | 10845 | | Default Value | 10800 |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwaLogLevel |
|
|
| Description | MSCA Log Level. Different log levels can be set for obtaining more debug information. | | Current Value | error | | Default Value | error |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwaLogRotate |
|
|
| Description | Enable log rotation of files based on size (Yes/No). | | Current Value | Yes | | Default Value | Yes |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwaLogFileSize |
|
|
| Description | MSCA Log File Size. If log rotation is enabled, then rotation occurs when log file exceeds this size. | | Current Value | 10000000 | | Default Value | 10000000 |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwaDropConnectionTimeout |
|
|
| Description | MSCA Drop Connection Timeout. MSCA Server allows a client that was disconnected to reconnect within the time mentioned below in minutes. | | Current Value | 5 | | Default Value | 5 |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwaStaleSessionTimeout |
|
|
| Description | MSCA Stale Session Timeout. MSCA Server disconnects a client after the client is idle for mwa.StaleSessionTimeout minutes. | | Current Value | 60 | | Default Value | 60 |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwaDispatcherThreadCount |
|
|
| Description | Specify number of worker threads to start from the dispatcher process | | Current Value | 15 | | Default Value | 15 |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwaDispatcherClientsPerWorker |
|
|
| Description | Specify number of clients that each dispatcher worker thread can handle | | Current Value | 10 | | Default Value | 10 |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwaJVMb |
|
|
| Description | MSCA Compatability Setting for JVM | | Current Value | FALSE | | Default Value | FALSE |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwaActivateLOVByEnter |
|
|
| Description | Used to specify whether user would like to retain old LOV behavior, i.e. LOV will be activated by ENTER or not | | Current Value | FALSE | | Default Value | FALSE |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwaSubmenuChangeOrgResp |
|
|
| Description | Specifies whether Change Responsibility and Change Organization menu items should appear on submenus; if TRUE, then these menu items will appear on the main menu and submenus; if FALSE, then these menu items will only appear on the main menu; the default value is FALSE. | | Current Value | FALSE | | Default Value | FALSE |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwatop |
|
|
| Description | Location of Product Top for MWA | | Current Value | /slot/ems2815/appmgr/apps/apps_st/appl/mwa/12.0.0 | | Default Value | %s_at3%%/%mwa%/%12.0.0 |
|
| The context variable is found in the following templates under FND_TOP |
| Template | Configuration Directive |
|---|
| oc4j_properties_1013.tmp | oracle.apps.mwa=%s_mwatop% |
|
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwaname |
|
|
| Description | Instance Specific Name of the 'Oracle MWA' Service. | | Current Value | Oracle MWA Service az1mq206_rws60043rems | | Default Value | Oracle MWA Service %s_contextname% |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwastatus |
|
|
| Description | Status of the 'Oracle MWA' service. Can be 'enabled' or 'disabled'. The default value is 'disabled'. | | Current Value | enabled | | Default Value | disabled |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwalog |
|
|
| Description | Complete path to the Log File for the 'Oracle MWA' Service. | | Current Value | /slot/ems2815/appmgr/inst/apps/az1mq206_rws60043rems/logs/appl/admin/log/mwactl.txt | | Default Value | %s_logs_dir%%/%appl%/%admin%/%log%/%mwactl.txt |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwatimeout |
|
|
| Description | Timeout for the 'ORACLE MWA' Service in seconds. | | Current Value | 100 | | Default Value | 100 |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
Context Variable : s_mwactrl |
|
|
| Description | Name of the script that controls the 'Oracle MWA' Service. | | Current Value | /slot/ems2815/appmgr/inst/apps/az1mq206_rws60043rems/admin/scripts/mwactlwrpr.sh | | Default Value | %s_config_home%\admin\scripts\mwactlwrpr.cmd |
|
| The context variable is not found in any template under FND_TOP |
| The context variable is not found in any template under AD_TOP |
| |
| |
| |
Copyright 2008 Oracle Corporation. All Rights Reserved. Oracle Corporation |