Technology Stack (TXK) AutoConfig Context Variable Report

Entered Keywords mwa
Matched Context Variables s_mwaPortNo, s_mwaTelnetPortNo, s_mwaDispatcherPort, s_mwaLogLevel, s_mwaLogRotate, s_mwaLogFileSize, s_mwaDropConnectionTimeout, s_mwaStaleSessionTimeout, s_mwaDispatcherThreadCount, s_mwaDispatcherClientsPerWorker, s_mwaJVMb, s_mwaActivateLOVByEnter, s_mwaSubmenuChangeOrgResp, s_mwatop, s_mwaname, s_mwastatus, s_mwalog, s_mwatimeout, s_mwactrl

Context Variable : s_mwaPortNo

Description       MSCA Server Port Number
Current Value    10290-10295 
Default Value     10200 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwaTelnetPortNo

Description       MSCA Telnet Server Port Number
Current Value    10290,10292,10294 
Default Value     10200 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwaDispatcherPort

Description       MSCA Dispatcher Port Number
Current Value    10845 
Default Value     10800 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwaLogLevel

Description       MSCA Log Level. Different log levels can be set for obtaining more debug information.
Current Value    error 
Default Value     error 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwaLogRotate

Description       Enable log rotation of files based on size (Yes/No).
Current Value    Yes 
Default Value     Yes 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwaLogFileSize

Description       MSCA Log File Size. If log rotation is enabled, then rotation occurs when log file exceeds this size.
Current Value    10000000 
Default Value     10000000 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwaDropConnectionTimeout

Description       MSCA Drop Connection Timeout. MSCA Server allows a client that was disconnected to reconnect within the time mentioned below in minutes.
Current Value   
Default Value    
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwaStaleSessionTimeout

Description       MSCA Stale Session Timeout. MSCA Server disconnects a client after the client is idle for mwa.StaleSessionTimeout minutes.
Current Value    60 
Default Value     60 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwaDispatcherThreadCount

Description       Specify number of worker threads to start from the dispatcher process
Current Value    15 
Default Value     15 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwaDispatcherClientsPerWorker

Description       Specify number of clients that each dispatcher worker thread can handle
Current Value    10 
Default Value     10 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwaJVMb

Description       MSCA Compatability Setting for JVM
Current Value    FALSE 
Default Value     FALSE 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwaActivateLOVByEnter

Description       Used to specify whether user would like to retain old LOV behavior, i.e. LOV will be activated by ENTER or not
Current Value    FALSE 
Default Value     FALSE 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwaSubmenuChangeOrgResp

Description       Specifies whether Change Responsibility and Change Organization menu items should appear on submenus; if TRUE, then these menu items will appear on the main menu and submenus; if FALSE, then these menu items will only appear on the main menu; the default value is FALSE.
Current Value    FALSE 
Default Value     FALSE 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwatop

Description       Location of Product Top for MWA
Current Value    /slot/ems2815/appmgr/apps/apps_st/appl/mwa/12.0.0 
Default Value     %s_at3%%/%mwa%/%12.0.0 
The context variable is found in the following templates under FND_TOP
Template Configuration Directive
oc4j_properties_1013.tmp oracle.apps.mwa=%s_mwatop%
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwaname

Description       Instance Specific Name of the 'Oracle MWA' Service.
Current Value    Oracle MWA Service az1mq206_rws60043rems 
Default Value     Oracle MWA Service %s_contextname% 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwastatus

Description       Status of the 'Oracle MWA' service. Can be 'enabled' or 'disabled'. The default value is 'disabled'.
Current Value    enabled 
Default Value     disabled 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwalog

Description       Complete path to the Log File for the 'Oracle MWA' Service.
Current Value    /slot/ems2815/appmgr/inst/apps/az1mq206_rws60043rems/logs/appl/admin/log/mwactl.txt 
Default Value     %s_logs_dir%%/%appl%/%admin%/%log%/%mwactl.txt 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwatimeout

Description       Timeout for the 'ORACLE MWA' Service in seconds.
Current Value    100 
Default Value     100 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 

Context Variable : s_mwactrl

Description       Name of the script that controls the 'Oracle MWA' Service.
Current Value    /slot/ems2815/appmgr/inst/apps/az1mq206_rws60043rems/admin/scripts/mwactlwrpr.sh 
Default Value     %s_config_home%\admin\scripts\mwactlwrpr.cmd 
The context variable is not found in any template under FND_TOP
The context variable is not found in any template under AD_TOP
 
 
 

Copyright 2008 Oracle Corporation. All Rights Reserved.
Oracle Corporation